Riken FI-8000P

PRODUCT CODE:

FI-8000P

For Anesthetic Vaporizer Calibration

 

DOES IT ALL!

Latest development in the line of

RIKEN GAS INDICATORS

based on the optical interferometer principle.

 

The RIKEN FI-8000P makes all calculations and adjustments for range, anesthetic, and conversion factors automatically.

Overview

Accessories

Documents

Product Literature

FAQs

Riken FI-8000P

A.M. Bickford, Inc is partnered with the Riken Keiki Company to distribute the Riken Anesthetic Gas Analyzers. For over 40 years, A.M. Bickford has been selling, servicing and calibrating Riken Keiki 1806H, 1802D, FI-21 and now the FI-8000 analyzers. The FI-8000P  is manufactured by the Riken Keiki Co. Ltd., the world leader in gas detection and sensor technologies.  It is a light weight, mobile and easy to use solution to test anesthetic vaporizers calibration.

The FI-8000P Features

  • 3 AA Batteries
  • Large LCD Screen
  • Built In Sample Pump
  • 2 Carrier Gases (02 & Air)
  • 4 Anesthetic Gases (Sevoflurane, Isoflurane, Desflurane, Halothane)
  • Direct Digital Readout
  • No Conversation Factors
  • Self Checking Readout on Display

Model FI-8000P Quick Operation Guide

 

  1. While pressing an holding down "REF/CAL" button, Press "POWER/ENTER" button for ONE  BEEP and then release both buttons. Unit and pump turns on.
  2. You are now in "SET UP MODE-1-SELECT GAS"
  3. Press "POWER/ENTER" button twice for TWO BEEPS. "SPE" number will start flashing
  4. You can now select what gas and carrier gas you need to check your vaporizer.                                   Use "REF/CAL ^ (scroll up) or REC v (scroll down)" to make your selection
  5. When the correct gas is selected hold down "POWER/ENTER" for TWO BEEPS.                           (This time you must hold down the button for TWO BEEPS then release button)
  6. Press "REC" button down to # -6- "START MEAS Yes/ENTER/NO ESC"
  7. If you have the correct anesthetic and carrier gas press "ENTER" button for ONE BEEP
  8. Now set the AIR Cal, HOLD DOWN "REF CAL" for ONE BEEEP (then release)
  9. With the unit teed into a common gas outlet, set the vaporizer to needed percent settings to             record readings.  The pump stays on for the whole process. Record your readings.
  10. When done with your vaporizer calibration check, hold down "POWER/ENTER" button for          THREE BEEPS and the unit and pump will turn off.

Click on PDF icon to learn more about Riken FI-8000

RIKEN FI-8000

 

Here at A.M. Bickford, Inc., we always strives to answer all your questions so that you experience with us is the best.

HERE ARE SOME COMMON FREQUENTLY ASK QUESTIONS.

  •   1. Does A.M. Bickford CALIBRATE Riken Anesthetic Gas Analyzers?

    a:

    YES!

     

    We calibrate 1806H 1802D FI-21 & FI-8000P.

     

    CLICK HERE to receive quote.

  •   2. What is INCLUDED with the FI-8000P?

    a:

    FI-8000Pt COMES WITH:

    • Carry Case
    • 3 AA Batteries (installed)
    • Shoulder Strap
    • Operating Manual
    • Sample Tube
    • Sample T
    • Absorption Tube
    • Filter Tube
  •   3. How long is the FI-8000P WARRANTY?

    a:

    FI-8000P GIVES A 1 YEAR WARRANTY

  •   4. How much does the FI-8000P WEIGH?

    a:

    FI-8000P WEIGHS 2.6 POUNDS:

  •   5. What are the FI-8000P DIMENSIONS?

    a:

     APPROXIMATE MEASUREMENTS IN MM : 154 (W) X 127 (H) X 81 (D)

  •   6. What SIZE BATTERIES does the FI-8000P use?

    a:

    3 AA BATTERIES

  •   7. HOW LONG will the BATTERIES LAST?

    a:

    THE TIMES MAY VARY DEPENDING ON USAGE BUT THE ESTIMATED TIME IS 80 HOURS

  •   8. What is the FLOW RATE of the BUILD-IN PUMP?

    a:

    THE FLOW RATE IS 400CC/MIN (0.4L/MIN)

  •   9. Can I TURN OFF the FI-8000P AUTOMATIC PUMP?

    a:

    NO, THE PUMP WILL CONTINUOUSLY RUN WHILE THE UNIT IS ON.

  • 10. Can I TURN OFF the FI-8000P "BEEPING"?

    a:

    NO

  • 11. The LCD Screen (FI-21 & FI-8000P) is displaying Low Contrast, Low Brightness or ERROR message? WHAT SHOULD I DO?

    a:

    CONTACT A.M. BICKFORD IMMEDIATELY FOR SERVICE AND RECOMMENDATIONS

  • 12. HOW MANY Data Recording Points can the FI-8000P STORE?

    a:

     256 POINTS CAN BE RECORDED. IF THE MAXIMUM IS EXCEEDED THE LCD SCREEN WILL DISPLAY "RECORD  FULL"

  • 13. How do I SWITCH from ONE ANESTHETIC GAS TO ANOTHER?

    a:

    FOLLOW THESE STEPS:

     

    • The FI-8000P must be turned off to and turned back one to switch from one agent to another.
    • Press and hold down "POWER/ENTER" button for 3 BEEPS. The unit and pump will turn off.
    • Press and hold down "REF/CAL" and "POWER/ENTER" button at the same time for one beep.
    • The LCD screen will display "SET UP MODE -1- SELECT GAS".

     

  • 14. Does A.M. Bickford, Inc CALIBRATE the FI-8000P?

    a:

    YES!

     

    we provide calibration services for all Riken Anesthetic Gas Analyzers

     

    CLICK HERE to receive quote.